Nortec SAM-e Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Nortec SAM-e. Nortec SAM-e User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 62
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SAM-e
Installation and
Operation Manual
Includes installation, operation
maintenance and troubleshooting
information for your SAM-e and Mini
SAM-e Short Absorption Manifold.
1507619-H| 10 SEP 2014
Important: Read and save these instructions. This guide to be left with equipment.
Zobrazit stránku 0
1 2 3 4 5 6 ... 61 62

Shrnutí obsahu

Strany 1 - Operation Manual

SAM-e Installation and Operation Manual Includes installation, operation maintenance and troubleshooting information for your SAM-e and Mini

Strany 2 - SERIAL #

7 | Installation SAM-e In-Duct

Strany 3 - Contents

SAM-e Installation | 8 Typical SAM-e Installation General SAM-e Assembly Diagram

Strany 4 - 1

9 | SAM-e Installation 1 Fasten support brackets to header using 5/16” washers and 5/16” nylon lock-nuts. 2 Place header on duct floor and

Strany 5 - Introduction

SAM-e Installation | 10 3 Insert tube into insertion stop washer and then into grommet. Wetting grommet with water will make assembly easier. E

Strany 6 - Identify your Components

11 | SAM-e Installation 5 Attach tube support bracket using supplied 1/4” lock-washer and 1/4” hex screws. 6 No mounting frame – proceed t

Strany 7 - SAM-e Installation

SAM-e Installation | 12 6A If no mounting frame is supplied: Attach bracket flanges to tube support bracket using 5/16” screws, washers, and nylon

Strany 8 - How to Use this Manual

13 | SAM-e Installation 7 Slide frame sides into frame base. 8 Attach Frame Pivot using 5/16” bolt, washer, and nylon lock-nut. Side V

Strany 9 - SAM-e Installation

SAM-e Installation | 14

Strany 10 - SAM-e In-Duct

15 | SAM-e Installation Installation in Vertical Duct

Strany 11 - Typical SAM-e Installation

SAM-e Installation | 16 1 Complete assembly following Steps 1 through 8 on pages 9 through 13. Install complete assembly into duct at 10° angl

Strany 12 - 9

Thank you for choosing Nortec. Proprietary Notice This document and the information disclosed herein are proprietary

Strany 13 - SAM-e Installation

17 | SAM-e Installation Mini SAM-e Installation Procedures

Strany 14 - 11

SAM-e Installation | 18 Mini SAM-e Assembly General Installation

Strany 15 - SAM-e Installation

19 | SAM-e Installation 1 Place header into duct. Use supplied template to cut holes for steam and condensate parts. Attach header to duct using

Strany 16 - 13

SAM-e Installation | 20

Strany 17 - SAM-e Installation

21 | SAM-e Installation Plumbing

Strany 18 - Vertical Duct

SAM-e Installation | 22 SAM-e with Pressure Steam Pressurized Plumbing with External Separator • Steam components in grey provided by Nortec. • T

Strany 19 - SAM-e Installation

23 | SAM-e Installation Pressurized Plumbing without External Separator Note: The SAM-e header functions as a steam separator, therefore an ext

Strany 20 - Installation Procedures

SAM-e Installation | 24 Internal Baffle Plate

Strany 21 - SAM-e Installation

25 | SAM-e Installation Condensate Pump Plumbing When pressurized steam enters SAM-e, pressure drops down to almost atmospheric p

Strany 22 - 19

SAM-e Installation | 26 Mini SAM-e with Pressurized Steam Mini SAM-e Pressurized with External Separator • Steam components in grey provided by

Strany 23 - SAM-e Installation

Contents 2 Introduction 2 Location of Humidifier’s Manifold in an Air Conditioning System 4 Identify your Components 5 How to Use this M

Strany 24 - Plumbing

27 | SAM-e Installation Mini SAM-e Pressurized without External Separator • Max steam pressure of 15 psig when no

Strany 25 - SAM-e with Pressure Steam

SAM-e Installation | 28 Mini SAM-e Condensate Pump Plumbing When pressurized steam enters Mini SAM-e, pressure drops down

Strany 26 - 23

29 | SAM-e Installation SAM-e with Atmospheric Steam Atmospheric Plumbing Atmospheric steam inlet Use Nortec supplied steam hose and gear c

Strany 27 - Internal Baffle Plate

SAM-e Installation | 30 Plumbing with Drain Water Cooler 1" NPT to 3/4” NPT Reducer (Supplied By Others) 1" Air Gap To Prevent

Strany 28 - 25

31 | SAM-e Installation Mini SAM-e with Atmospheric Steam Mini SAM-e with Atmospheric Steam Atmospheric steam inlet Use Nortec supplied steam ho

Strany 29 - SAM-e Installation

SAM-e Installation | 32

Strany 30 - 27

33 | SAM-e Installation Atmospheric Steam Lines

Strany 31 - SAM-e Installation

SAM-e Installation | 34 Plumbing Pressurized SAM-e For pressurized steam line installation instructions, refer to LiveSteam Steam Injection Humidifie

Strany 32 - SAM-e with Atmospheric Steam

35 | SAM-e Installation Electrode Steam-Line Table 1: Electrode Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size

Strany 33 - SAM-e Installation

SAM-e Installation | 36 Gas Steam-Line Table 2: Gas Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size Stainless st

Strany 34 - 8” min

1 | SAM-e Installation CAUTION: Plumbing  Plumbing to be performed by a licensed plumber.  Drain water from humidifier can be very hot. Do not

Strany 35 - SAM-e Installation

37 | SAM-e Installation SE Steam Line Table 3: SE Steam-Line Unit No. of Steam Outlets Steam output [ lb ] MED-L copper tube nominal steam line siz

Strany 36 - Atmospheric Steam Lines

SAM-e Installation | 38 NHRS Steam-Line Table 4: SE Steam-Line Humidifier Steam output [ lb ] MED-L copper tube nominal steam line size Stainless ste

Strany 37

39 | SAM-e Installation Effective Length of Typical Steam-Line Fittings Table 5: Effective length of Typical Steam-Line Fittings Nominal tube size St

Strany 38 - Electrode Steam-Line

SAM-e Installation | 40 Atmospheric SAM-e Condensate Drainage 1 SAM-e condensate outlet connection is male 3/4”-NPT. 2 Condensate from SAM-e must b

Strany 39 - Gas Steam-Line

41 | SAM-e Installation Steam Lines and Condensate Returns Use appropriate slope Figure 1: Slope Figure 2: Insulate pipe

Strany 40 - SE Steam Line

SAM-e Installation | 42 Figure 4: Distributor Above Humidifier (Copper Steam Line) Figure 5: Distributor Above Humidifier (Hose)

Strany 41

43 | SAM-e Installation Figure 6: Steam Distributor Below Humidifier (Hose) Figure 7: Steam Distributor Below Humidifier and Obstruction (Hose)

Strany 42 - Material for Steam Lines

SAM-e Installation | 44 Figure 8: Long Steam Run

Strany 43 - SAM-e Installation

45 | SAM-e Installation Atmospheric Steam Lines

Strany 44 - Figure 3: Condensate Traps

SAM-e Installation | 46 Insulation Factory-Installed Insulation 1 Unpack tubes and headers. Inspect tubes to ensure that stainless insulation cove

Strany 45

SAM-e Installation | 2 Introduction Receiving and Unpacking Equipment Check packing slip to ensure ALL material has been delivered. Each humidifi

Strany 46

47 | SAM-e Installation Quantity of Insulating Covers Required to Cover SAM-e Tube Table 7: Quantity of Insulating Covers Required to Cover SAM-e Tub

Strany 47

SAM-e Installation | 48 Header Installation 1 Install header insulation for SAM-e; expand header insulation to fit over header and slide on. Ensur

Strany 48

49 | SAM-e Installation SAM-e Insulation Retrofit 1 Install header wrap around header. 2 Tuck header wrap underneath rubber grommets and

Strany 49 - Insulation

SAM-e Installation | 50 FOR DUAL INLETS; INSULATE HEADER AS SHOWN ON PREVIOUS PAGE. INSULATE SECOND INLET AS SHOWNROLL SHIELD TO CREATE OVERLAPDETAI

Strany 50

51 | SAM-e Installation 3 Apply shields to tubes and secure with stainless straps. 4 Completed Tube.

Strany 51 - Header Installation

SAM-e Installation | 52 Mini SAM-e Insulation Retrofit 1 Connect Top and Bottom heat shields together (snap fit) . 2 Completed header.

Strany 52 - SAM-e Insulation Retrofit

53 | SAM-e Installation 3 Fit shields to tubes. 4 Secure with stainless straps.

Strany 53 - SAM-e Installation

SAM-e Installation | 54 5 Completed tube.

Strany 54 - 51

55 | SAM-e Installation Troubleshooting, Maintenance, Spare Parts

Strany 55 - Completed header

SAM-e Installation | 56 Troubleshooting Steam tubes discharge water: 1 Steam supply pipe is not insulated. 2 Steam supply pipe not properly drain

Strany 56 - 53

3 | SAM-e Installation Identify your Components

Strany 58 - Spare Parts

57 | SAM-e Installation Warranty Nortec Humidity Inc. and/or Nortec Humidity Ltd. (hereinafter collectively referred to as THE COMPANY), warran

Strany 59 - Maintenance

U.S.A. 1860 Renaissance Blvd. Sturtevant, WI 53177 826 Proctor Avenue Ogdensburg, NY 13669 CANADA 2740 Fenton Road Ottawa, Ontario K1T 3T7 TEL:

Strany 60

SAM-e Installation | 4 Identify your Optional Components

Strany 61 - Warranty

5 | SAM-e Installation How to Use this Manual SAM-e - In Duct Section 2 Follow steps 1-9 SAM-e - Vertical Duct Installation Section 4 Foll

Strany 62

SAM-e Installation | 6 Plumbing Section 6 6A - SAM-e Pressure Steam 6B - mini SAM-e Pressure Steam 6C - SAM-e Atmospheric Steam 6D - mini SAM-e Atmos

Komentáře k této Příručce

Žádné komentáře